SERIES
R102


INSTALLATION INSTRUCTIONS

 

INSTALLER TO INSURE THAT VOLTAGE OF RETROFIT ASSEMBLY IS THE SAME VOLTAGE AS THE UNIT
TO BE RETROFITTED.

INSTALLER INSURE THAT WIDTH OF HOUSING IS BETWEEN 3-3/4" AND 7-1/2".

TURN OFF POWER TO FIXTURE BEING RETROFITTED.

REMOVE EXISTING LAMPS.

REMOVE EXISTING BALLAST/WIREWAY COVER(S).

CUT BALLAST BLACK & WHITE LEADS WITHIN 8 TO  8 INCHES OF BRANCH CIRCUIT CONDUCTORS.

REMOVE EXISTING LAMP HOLDERS, SOCKET PLATES AND END CAPS.

REMOVE BALLAST AND DISCARD IN ACCORDANCE WITH LOCAL CODES AND/OR HAZARDOUS MATERIAL
REQUIREMENTS.

"TEK" SCREW MOUNTING ANGLE TO TOP OF HOUSING, INDEXING OFF 7/8" KNOCK OUT.

PULL 2 - 3 INCHES OF BEAD-CHAIN THROUGH KEY- HOLE SLOT IN MOUNTING ANGLE AND SECURE.

CONNECT BALLAST LEADS AND GROUND TO APPROPRIATE EXISTING CONNECTIONS THEREIN
EXISTING HOUSING.

ONCE CONNECTION IS MADE PRESS R316 TIGHTLY AGAINST EXISTING HOUSING AND SECURE BY
PULLING CHAIN THROUGH HOLE.  ONCE HOUSING IS SNUG, SECURE CHAIN BY SLIDING INTO SLOT.

WHEN HOUSING IS SECURE COIL EXCESS BEAD-CHAIN INTO CAP AND PUSH ARROW CLIP
INTO HOLE IN HOUSING.

TO REMOVE CAP PULL LIGHTLY AND DISENGAGE ARROW CLIP.

ONCE RETROKIT IS INSTALLED ATTACH END PLATE AND SECURE WRAPAROUND LENS.

INSTALL LAMPS AND TURN ON POWER.

 

 

 